STANDARD 5A MOLECULAR SIEVE

Description

Standard 5A molecular sieve is manufactured for use in air prepurification units to remove water, carbon dioxide, and hydrocarbons from feed gas. The removal of these contaminants is essential for compressed air systems and for purifying gas streams. This molecular sieve offers a high adsorption capacity for impurities, especially water.

  • used to purify air feed gas
  • capable of removing water, carbon dioxide, and light hydrocarbons
  • allows gas to be further separated or otherwise used in compressors
  • offers an advantageous adsorption capacity for water

Chemical Formula

(Y)a x [(AlO2)a(SiO2)b] x cH2O      (Y = Na, Ca)

Specifications

Packaging Options:

Beads: 2,204.6lb / Super Sack – 330.7lb / Drum
Pellets: 2,204.6lb / Super Sack – 275.6lb / Drum

Standard 5A Molecular Sieve
Beads
Pellets
Property
Unit
4×8 Mesh
8×12 Mesh
1/8 Inch
1/16 Inch
Diameter
mm
2.5-5.0
1.6-2.5
1.5-1.8
3.0-3.3
Bulk Density
lb/ft3
43.1-46.8
44.9-48.7
43.1-46.8
42.4-46.2
Crush Strength
lbf
≥15.7
≥5.6
≥6.7
≥13.5
Static Water Adsorption
wt%
≥21.5
≥21.5
≥21.0
≥21.0
Static CO2 Adsorption
wt%
≥15.0
≥15.0
≥15.0
≥15.0
Attrition
wt%
≤0.1
≤0.1
≤0.4
≤0.4
Moisture Content
wt%
≤1.5
≤1.5
≤1.5
≤1.5

industries used:

  • air separation
  • compressed air
  • feed gas dehydration
  • inert gas purification

Connect with us…

If you are interested in learning more about this product, please reach us by your preferred method. Our team is happy to hear your interests and assist you to meet your specific needs.

Hengye Inc.
11999 Katy Freeway, Suite 588, Houston, Texas 77079
Toll Free: +1 (844) 308-3271
Office: (832) 288-4288
Fax: (832) 288-4230
info@hengyeinc.com

Storage

As an adsorbent, molecular sieve should not be left exposed to open air and should be stored in dry conditions with air-proof packaging.